Arizona Instrument
Computrac
MAX 5000XL
MOISTURE ANALYZER
USER MANUAL
700-0113-A
Firmware Revision 3.0X
April 2008
Arizona Instrument LLC
1912 W 4
th
Street
Tempe, AZ 85281
(800) 528-7411
(602) 470-1414
Fax (480) 804-0656
http://www.azic.com
email:
[email protected] - International
[email protected] - Customer Support
Vedere la pagina 0
1 2 3 4 5 6 ... 91 92

Sommario

Pagina 1 - MAX 5000XL

Arizona Instrument Computrac MAX 5000XL MOISTURE ANALYZER USER MANUAL 700-0113-A Firmware Revision 3.0X April 2008 Arizona Instrument LLC 1912 W

Pagina 2 - MAX 5000XL

AZI Customer Service 800-528-7411 or 602-470-1414 Page 10 of 92 3.1. Hardware The MAX 5000XL consists of:  A ceramic convection air oven  A p

Pagina 3 - TABLE OF CONTENTS

AZI Customer Service 800-528-7411 or 602-470-1414 Page 11 of 92 3.3. Inventory  Carefully unpack the instrument and locate the following items:

Pagina 4

AZI Customer Service 800-528-7411 or 602-470-1414 Page 12 of 92 4. INSTRUMENT SETUP Contact Arizona Instrument Customer Service at 800-528-7411 or

Pagina 5

AZI Customer Service 800-528-7411 or 602-470-1414 Page 13 of 92 4.1. Interior of Test Chamber  Remove the sample pan support from its separate bo

Pagina 6

AZI Customer Service 800-528-7411 or 602-470-1414 Page 14 of 92 4.2. AC Power Connection The MAX 5000XL can be used with a 100-130 VAC or a 2

Pagina 7

AZI Customer Service 800-528-7411 or 602-470-1414 Page 15 of 92 All accessory equipment, printer, computer, etc., should be connected before applyin

Pagina 8 - BOX FOR PAN SUPPORT

AZI Customer Service 800-528-7411 or 602-470-1414 Page 16 of 92  After power-up, the balance temperature will be stabilized for high temperature t

Pagina 9 - 3. INSTRUMENT DESCRIPTION

AZI Customer Service 800-528-7411 or 602-470-1414 Page 17 of 92 To set up the MAX 5000XL, begin at the Main Test Screen and press [Menu], (center k

Pagina 10 - Hardware

AZI Customer Service 800-528-7411 or 602-470-1414 Page 18 of 92  Move the selection box down to REPORT START and press [ENT]. Select between: 

Pagina 11 - Inventory

AZI Customer Service 800-528-7411 or 602-470-1414 Page 19 of 92 4.5. Connecting a Computer If you wish to monitor the test with a computer, conne

Pagina 12 - 4. INSTRUMENT SETUP

AZI Customer Service 800-528-7411 or 602-470-1414 Page 2 of 92 Computrac MAX 5000XL PROPRIETARY RIGHTS NOTICE The material in this manual cont

Pagina 13 - Interior of Test Chamber

AZI Customer Service 800-528-7411 or 602-470-1414 Page 20 of 92 4.7. Calibrate the Balance - 50 gram weight NOTE: The MAX 5000XL must be powered on

Pagina 14 - AC Power Connection

AZI Customer Service 800-528-7411 or 602-470-1414 Page 21 of 92 After placing a clean pan on the balance, close the lid. The screen will display “C

Pagina 15

AZI Customer Service 800-528-7411 or 602-470-1414 Page 22 of 92 4.8. Weight Test To ensure proper calibration and become familiar with the instrum

Pagina 16 - Contrast Adjustment

AZI Customer Service 800-528-7411 or 602-470-1414 Page 23 of 92 5. MAIN MENU Press [MENU] to display the MAIN MENU. 5.1. Memory Starts Men

Pagina 17

AZI Customer Service 800-528-7411 or 602-470-1414 Page 24 of 92 Editing Test Parameters The memory start parameters may be edited by highlighting a

Pagina 18 -  Select NO if you do not

AZI Customer Service 800-528-7411 or 602-470-1414 Page 25 of 92 Temperatures This menu gives access to three temperature parameters, an oven stable

Pagina 19 - Connecting a Computer

AZI Customer Service 800-528-7411 or 602-470-1414 Page 26 of 92 The possible displays are:  CHAMBER STABLE - The oven has been at a stable tempera

Pagina 20

AZI Customer Service 800-528-7411 or 602-470-1414 Page 27 of 92 When the prediction is sufficiently reliable, the test ends and the predicted result

Pagina 21 - “CLOSE LID”

AZI Customer Service 800-528-7411 or 602-470-1414 Page 28 of 92  Some samples contain more than one volatile material, for example, nylon resin

Pagina 22 - Weight Test

AZI Customer Service 800-528-7411 or 602-470-1414 Page 29 of 92  Reliability – This feature is similar to Rate but is based on a percent of accur

Pagina 23 - 5. MAIN MENU

AZI Customer Service 800-528-7411 or 602-470-1414 Page 3 of 92 TABLE OF CONTENTS 1. WARNINGS AND SAFETY INFORMATION -----------------------------

Pagina 24

AZI Customer Service 800-528-7411 or 602-470-1414 Page 30 of 92  Inside Limits and Outside Limits - Selections of no sound, one beep, two beeps or

Pagina 25

AZI Customer Service 800-528-7411 or 602-470-1414 Page 31 of 92  Sample Tare – Records the average initial sample weight during a programmable per

Pagina 26

AZI Customer Service 800-528-7411 or 602-470-1414 Page 32 of 92 Result Display Options  DISPLAY RESULT AS: Selects the final display value of moi

Pagina 27

AZI Customer Service 800-528-7411 or 602-470-1414 Page 33 of 92 Linked Test Options Linking tests enables multiple adjoining memory starts to be ru

Pagina 28

AZI Customer Service 800-528-7411 or 602-470-1414 Page 34 of 92 Use This Test Weight For Total Calculations?  Toggle this parameter to YES if th

Pagina 29

AZI Customer Service 800-528-7411 or 602-470-1414 Page 35 of 92 CUT Memory Start This command removes a memory start, which can be optionally inser

Pagina 30

AZI Customer Service 800-528-7411 or 602-470-1414 Page 36 of 92 PRINT Memory Start This command prints the stored parameters. All of the numbered M

Pagina 31

AZI Customer Service 800-528-7411 or 602-470-1414 Page 37 of 92 5.2. Stored Data Menu This function is used to work with data stored in the instr

Pagina 32

AZI Customer Service 800-528-7411 or 602-470-1414 Page 38 of 92 To analyze a set of data: Use the arrow keys to highlight the data items to be i

Pagina 33

AZI Customer Service 800-528-7411 or 602-470-1414 Page 39 of 92 View Stored Data This function is used to view a list of results for a selected test

Pagina 34

AZI Customer Service 800-528-7411 or 602-470-1414 Page 4 of 92 Report Items to Print ...

Pagina 35

AZI Customer Service 800-528-7411 or 602-470-1414 Page 40 of 92 5.3. Calibration Menu Balance Calibration Balance calibration is explained and pe

Pagina 36

AZI Customer Service 800-528-7411 or 602-470-1414 Page 41 of 92  As soon as the instrument detects weight on the balance, the prompt “CLOSE LID” a

Pagina 37 - Stored Data Menu

AZI Customer Service 800-528-7411 or 602-470-1414 Page 42 of 92 High Temperature Lift Calibration The MAX 5000XL High Temperature Lift Calibration

Pagina 38

AZI Customer Service 800-528-7411 or 602-470-1414 Page 43 of 92 Temperature Calibration The MAX 5000XL temperature calibration routines will calibr

Pagina 39

AZI Customer Service 800-528-7411 or 602-470-1414 Page 44 of 92 Perform Calibration This selection starts the automatic process of calibration, and

Pagina 40 - Calibration Menu

AZI Customer Service 800-528-7411 or 602-470-1414 Page 45 of 92 View Cal Report The VIEW CAL REPORT selection provides information about the last c

Pagina 41 - “CLOSE LID”

AZI Customer Service 800-528-7411 or 602-470-1414 Page 46 of 92 Calibration Reminder Setup A TEMPERATURE CALIBRATION REMINDER is available to remind

Pagina 42

AZI Customer Service 800-528-7411 or 602-470-1414 Page 47 of 92 Temperature Calibration Instructions  Ensure the instrument is turned ON  A Tem

Pagina 43

AZI Customer Service 800-528-7411 or 602-470-1414 Page 48 of 92  The disk number is located on the probe fixture and should match the probe number

Pagina 44

AZI Customer Service 800-528-7411 or 602-470-1414 Page 49 of 92 Oven Cleaning This selection is the start of an oven cleaning process that burns of

Pagina 45

AZI Customer Service 800-528-7411 or 602-470-1414 Page 5 of 92 1. WARNINGS AND SAFETY INFORMATION The MAX 5000XL moisture analyzer complies with

Pagina 46

AZI Customer Service 800-528-7411 or 602-470-1414 Page 50 of 92 5.4. Setup Menu The SETUP MENU is used to program the MAX 5000XL with information

Pagina 47

AZI Customer Service 800-528-7411 or 602-470-1414 Page 51 of 92 Report Setup This menu allows the report outputs to be enabled and the printout to

Pagina 48

AZI Customer Service 800-528-7411 or 602-470-1414 Page 52 of 92 Report Items to Print Test results are available to be printed, sent to a computer,

Pagina 49

AZI Customer Service 800-528-7411 or 602-470-1414 Page 53 of 92 Data Format Setup This menu brings up the two categories of data, one display orie

Pagina 50 - Setup Menu

AZI Customer Service 800-528-7411 or 602-470-1414 Page 54 of 92 Access Key Setup This menu provides a means of preventing unauthorized access to m

Pagina 51

AZI Customer Service 800-528-7411 or 602-470-1414 Page 55 of 92 Although the following options are accessible in all MAX 5000XL instruments, the opt

Pagina 52

AZI Customer Service 800-528-7411 or 602-470-1414 Page 56 of 92 Special Features This menu provides optional features for the instrument. A Web Ser

Pagina 53

AZI Customer Service 800-528-7411 or 602-470-1414 Page 57 of 92  To add a new foil, select [ADD]. Follow the prompts to open the lid, place a fo

Pagina 54

AZI Customer Service 800-528-7411 or 602-470-1414 Page 58 of 92 5.6. Parameter Expert (Optional Feature) A Parameter Expert option can be purchased

Pagina 55

AZI Customer Service 800-528-7411 or 602-470-1414 Page 59 of 92 • This is an interim screen. Ensure you have the material properly prepared.

Pagina 56 - Sample Foils

AZI Customer Service 800-528-7411 or 602-470-1414 Page 6 of 92 HAZARDS FOR PERSONS OR EQUIPMENT POSED BY USING SPECIFIC SAMPLES: Flammables

Pagina 57

AZI Customer Service 800-528-7411 or 602-470-1414 Page 60 of 92 • Answer appropriately and the system will ask you to start the next test.

Pagina 58

AZI Customer Service 800-528-7411 or 602-470-1414 Page 61 of 92 •Again the system prompts to see if the temperature is too high, indicated by a b

Pagina 59

AZI Customer Service 800-528-7411 or 602-470-1414 Page 62 of 92 Optimize Temp/Speed/Repeatability The Parameter Expert Optimize feature determines

Pagina 60

AZI Customer Service 800-528-7411 or 602-470-1414 Page 63 of 92 •Optimization is complete and the memory start has been modified. Press OK and

Pagina 61

AZI Customer Service 800-528-7411 or 602-470-1414 Page 64 of 92 6. SAMPLE PREPARATION, TESTING AND ANALYSIS 6.1. Balance Temperature Stability T

Pagina 62

AZI Customer Service 800-528-7411 or 602-470-1414 Page 65 of 92 6.2. Preparing Granular and Powdery Samples The MAX 5000XL can be used to test a w

Pagina 63

AZI Customer Service 800-528-7411 or 602-470-1414 Page 66 of 92 6.4. Selecting the Optimum Sample Size Each particular sample will have its own o

Pagina 64

AZI Customer Service 800-528-7411 or 602-470-1414 Page 67 of 92 A typical drying curve is shown at the right. Section (A-B) represents the sample&a

Pagina 65

AZI Customer Service 800-528-7411 or 602-470-1414 Page 68 of 92 7.2. Determining Proper Test Temperature If the moisture of the sample material is

Pagina 66 - 7. PERFORMANCE ENHANCEMENT

AZI Customer Service 800-528-7411 or 602-470-1414 Page 69 of 92 7.3. Selection of Ending Criteria The decision of which ending criteria to use is

Pagina 67

AZI Customer Service 800-528-7411 or 602-470-1414 Page 7 of 92 2. PACKING AND SHIPPING INSTRUCTIONS IMPORTANT Movement, handling, and packaging o

Pagina 68

AZI Customer Service 800-528-7411 or 602-470-1414 Page 70 of 92 8. PERFORMANCE VERIFICATION Periodic checks of the system are recommended to verif

Pagina 69 - Selection of Ending Criteria

AZI Customer Service 800-528-7411 or 602-470-1414 Page 71 of 92 8.2. The Precision Weight Test The precision weight test consists of performing

Pagina 70 - 8. PERFORMANCE VERIFICATION

AZI Customer Service 800-528-7411 or 602-470-1414 Page 72 of 92 8.3. Sodium Tartrate Test The sodium tartrate test verifies the heater and forc

Pagina 71 - The Precision Weight Test

AZI Customer Service 800-528-7411 or 602-470-1414 Page 73 of 92 8.4. Precision Sodium Tartrate Test Perform the sodium tartrate test in Section 8

Pagina 72 - Sodium Tartrate Test

AZI Customer Service 800-528-7411 or 602-470-1414 Page 74 of 92 8.5. Retained Samples The weight test and the sodium tartrate test are usually su

Pagina 73

AZI Customer Service 800-528-7411 or 602-470-1414 Page 75 of 92 9. WEB SERVER An optional Web Server can be purchased for the MAX 5000XL. MS Inte

Pagina 74 - Retained Samples

AZI Customer Service 800-528-7411 or 602-470-1414 Page 76 of 92 9.2. LCD View The LCD screen is viewed by selecting LCD VIEW in the left bar. Thi

Pagina 75 - 9. WEB SERVER

AZI Customer Service 800-528-7411 or 602-470-1414 Page 77 of 92 9.4. Test Results Test results can be viewed by selecting TEST RESULTS in the lef

Pagina 76 - Memory Starts

AZI Customer Service 800-528-7411 or 602-470-1414 Page 78 of 92 10. ROUTINE MAINTENANCE The MAX 5000XL requires routine cleaning to keep the tes

Pagina 77 - Test Results

AZI Customer Service 800-528-7411 or 602-470-1414 Page 79 of 92 10.2. Shroud Gasket The shroud gasket creates a seal between the heater shroud and

Pagina 78 - 10. ROUTINE MAINTENANCE

AZI Customer Service 800-528-7411 or 602-470-1414 Page 8 of 92 Please save the shipping box and all packaging materials for future use. REMOVE THE

Pagina 79 - Insulator Seal

AZI Customer Service 800-528-7411 or 602-470-1414 Page 80 of 92 10.4. Oven Chamber Cleaning This selection is the start of an oven cleaning process

Pagina 80 - Oven Chamber Cleaning

AZI Customer Service 800-528-7411 or 602-470-1414 Page 81 of 92 10.5. Oven Vent Cleaning The oven vent should be inspected regularly for debris buil

Pagina 81 - External Filter Cleaning

AZI Customer Service 800-528-7411 or 602-470-1414 Page 82 of 92 10.7. Sample Pan Support  The sample pan support may need to be cleaned if high v

Pagina 82 - Lithium Battery Replacement

AZI Customer Service 800-528-7411 or 602-470-1414 Page 83 of 92 11. TROUBLE DIAGNOSIS SYMPTOM DIAGNOSIS REMEDY Final result is always zero or ne

Pagina 83 - 11. TROUBLE DIAGNOSIS

AZI Customer Service 800-528-7411 or 602-470-1414 Page 84 of 92 Moistures too high or solids too low Temperature set too high Lower temperature, se

Pagina 84

AZI Customer Service 800-528-7411 or 602-470-1414 Page 85 of 92 No heat (cont.) Door sensor failure Check display for LID OPEN message when open dur

Pagina 85

AZI Customer Service 800-528-7411 or 602-470-1414 Page 86 of 92 12. ACCESSORIES & MAINTENANCE PARTS CONSUMABLES 800-0037 Sodium Tartrate (50

Pagina 86

AZI Customer Service 800-528-7411 or 602-470-1414 Page 87 of 92 13. MAX 5000XL SPECIFICATIONS Feature Specification Size 18.5” length x 12.7”widt

Pagina 87 - Specification

AZI Customer Service 800-528-7411 or 602-470-1414 Page 88 of 92 Balance Calibration Menu driven calibration and verification in the field Annual f

Pagina 88

AZI Customer Service 800-528-7411 or 602-470-1414 Page 89 of 92 Repeatability Moisture Level >10% <5% Relative Standard Deviation >0.1%

Pagina 89

AZI Customer Service 800-528-7411 or 602-470-1414 Page 9 of 92 3. INSTRUMENT DESCRIPTION The Computrac MAX 5000XL is a high performance programma

Pagina 90 - 14. CHANGES

AZI Customer Service 800-528-7411 or 602-470-1414 Page 90 of 92 14. CHANGES Firmware Rev 3.0X, Manual Rev A 1. Initial release of MAX-5000XL. a

Pagina 91 - 15. WARRANTY

AZI Customer Service 800-528-7411 or 602-470-1414 Page 91 of 92 15. WARRANTY Arizona Instrument LLC warrants the Computrac MAX 5000XL to be free f

Pagina 92

AZI Customer Service 800-528-7411 or 602-470-1414 Page 92 of 92 TRADEMARK AND COPYRIGHT PROTECTION Computrac, Arizona Instrument and the stylized

Commenti su questo manuale